NADP/NADPH Assay Kit-WST

NADP/NADPH Assay Kit-WST

NADP/NADPH Assay

  • Product code
    N510  NADP/NADPH Assay Kit-WST
Unit size Price Item Code
100 tests $585.00 N510-10

Order
100 tests
Quantity may be adjusted within the cart.
Component
100 tests NADP/NADPH Extraction Buffer
NADP/NADPH Control Buffer
Standard Buffer
Assay Buffer
Dye Mixture
Enzyme
Standard
Filtration Tube
20 ml ×1
20 ml ×1
10 ml ×1
5.5 ml ×1
×1
110 μl ×1
×1
×12

Description

Principle
NADP/NADPH Assay Kit-WST enables quantitation of the amount of total NADP+/NADPH, NADPH and NADP+ in cells and measurement of their ratio.

Manual

Technical info

<

Cell lysate from a cell culture can be easily prepared via Deproteinzation using the extraction buffer and filtration tubes found within this kit. Intracellular NADPH levels can be quantified by heat treatment of cell lysate. Additionally, intracellular NADP+ levels can be determined by subtracting NADPH levels from independently measured total NADP+/NADPH levels.
This kit can be used to measure up to 12 samples and 8 standard samples (n=3). It is necessary to prepare additional filtration tubes when measuring more than 12 samples.

Study of NADP+/NADPH as Markers

The intracellular levels of NADP+ and NADPH are recognized as important metabolic markers in understanding how cancer cells & mitochondrial function are influenced by drug administration, genetic engineering, etc. In particular, the number of publications has increased, mainly within the United States, indicating that the assessment of intracellular metabolism is considered important to understanding cellular states.

Producing Accurate Data in Plate Assay

The quantitative analysis of NADPH and total NADP+/NADPH levels (0.01-1.00 μmol/l) is possible with the simultaneous measurement of the standard buffer supplied with this kit. When the total NADP+/NADPH levels in samples are higher than 1 μmol/l, the quantitative analysis becomes possible with the use of the diluted samples.
It has been confirmed that the NADP/NADPH Assay Kit-WST reacts with neither NAD+ nor NADH (see right diagram below).

Example of Measurements in Combination with Glutathione (GSH) Quantification Kit

Change in metabolic activity was examined when the anticancer drug doxorubicin (Dox) was added to Jurkat cells.
Dox was added to Jurkat cells (3×106 cells) to obtain a final concentration of 500 nmol/l Dox, and after 24 hours of incubation, NADP+/NADPH ratio and reduced/oxidized glutathione (GSH/GSSG) ratio were determined using the NADP/NADPH Assay Kit-WST and the GSSG/GSH Quantification Kit (Item#: G257), respectively, after the cells were washed in phosphate-buffered saline (PBS).

The results shown above are likely to be explained by the following mechanism. When DOX (doxorubicin) was added to cells, DOX radicals, along with NADP+, were generated by enzymatic reaction. DOX radicals form reactive oxygen species (ROS), which induces DNA damage and apoptosis. In the meantime, to eliminate ROS formed in cells, GSH is consumed and GSSG is increased. Moreover, NADPH is used to reduce GSSG to GSH, resulting in an increase in NADP+.

References

Open References

1) C. Henninger and G. Fritz, “Statins in anthracycline-induced cardiotoxicity: Rac and Rho, and the heartbreakers.”, Cell Death Dis. 2017, 8(1), e2564.
2) S. Mandziuk, R. Gieroba, A. Korga, W. Matysiak, B. Jodlowska-Jedrych, F. Burdan, E. Poleszak, M. Kowalczyk, L. Grzycka-Kowalczyk, E. Korobowicz, A. Jozefczyk and J. Dudka, “The differential effects of green tea on dose-dependent doxorubicin toxicity.”, Food Nutr Res., 2015, 59, 29754.
3) M. Nagaya, H. Hara, T. Kamiya and T. Adachi,"Inhibition of NAMPT markedly enhances plasma-activated medium-induced cell death in human breast cancer MDA-MB-231 cells.", Arch. Biochem. Biophys., 2019, 676, 108155.

Q & A

Q

How many samples can I measure?

A

* The number of samples that can be recorded when the sample is measured in triplicates.
The number of samples that can be measured when the standard sample is serially diluted from 2 μmol / l is shown in the table above. Using the data collected, a calibration curve is created at a total of 8 points (n=3).
It is necessary to create a calibration curve per measurement when you perform the measurement separately. If the measurement is done separately, the above sample number will be less.

Q

Can I purchase the filtration tube separately?

A

No, we don’t sell the filtration tube included in the kit separately. If you need additional supplies, you can also use a commercially available filtration tube.
Supplier:Pall Corporation
Product:Nanosep® MF Centrifugal Devices (MWCO:10K, color:blue)

Q

How stable is Working solution?

A

You can’t store the Working solution. Please prepare the Working solution prior to use. Please protect from light because the Working solution ins light-sensitive. The Working solution is stable for 4 hours at room temperature with protection from light.

Q

Our samples did not change in color, are there any reasons for this?

A

NAD level contained in the sample may be lower than the concentration that was measured using this kit.
Please increase the number of cells or lower the dilution ratio if you dilute the sample.

Handling and storage condition

Handling and storage condition
0-5°C, Protect from light, Protect from moisture
Contact